← All Advisories

CVE-2025-40946

Last refreshed2026-10-06

Status: UPDATED  |  Advisory ID: CVE-2025-40946

Key Details

CVECVE-2025-40946
CVSS Score / Version8.3 (High) / CVSS v3.1
Updated2026-06-17
CVSS VectorCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H
CVSS Proseattack vector is adjacent; attack complexity is low; privileges required is none; user interaction is none; scope is unchanged; confidentiality impact is low; integrity impact is high; availability impact is high.
Affected productssee table below
Classified asCWE-321 (Use of Hard-coded Cryptographic Key)

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
Siemensblueplanet 100 NX3 M8
Siemensblueplanet 100 TL3 GEN2
Siemensblueplanet 105 TL3
Siemensblueplanet 105 TL3 GEN2
Siemensblueplanet 110 TL3
Siemensblueplanet 125 NX3 M10
Siemensblueplanet 125 TL3
Siemensblueplanet 125 TL3 GEN2
Siemensblueplanet 137 TL3
Siemensblueplanet 150 TL3
Siemensblueplanet 150 TL3 GEN2
Siemensblueplanet 155 TL3
Siemensblueplanet 155 TL3 GEN2
Siemensblueplanet 165 TL3
Siemensblueplanet 165 TL3 GEN2
Siemensblueplanet 3.0 TL3-60.0 TL3
Siemensblueplanet 87.0 TL3
Siemensblueplanet 87.0 TL3 GEN2
Siemensblueplanet 92.0 TL3
Siemensblueplanet 92.0 TL3 GEN2
Siemensblueplanet gridsave 110 TL3-S
Siemensblueplanet gridsave 137 TL3-S
Siemensblueplanet gridsave 92.0 TL3-S
SubsystemsGeneral OT
SectorsMultiple

What to Know

A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions), blueplanet 150 TL3 (All versions), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 25.0 NX3-33.0 NX3 (All versions), blueplanet 3.0 NX3-20.0 NX3 (All versions), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 3.0-5.0 NX1 (All versions), blueplanet 360 NX3 M6 (All versions), blueplanet 50.0 NX3-60.0 NX3 (All versions), blueplanet 87.0 TL3 (All versions), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91), blueplanet hybrid 10.0 TL3 (All versions), blueplanet hybrid 6.0 NH3-12.0 NH3 (All versions). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access. (NVD)

What to Do

Monitor Siemens's web page for any future patch releases.

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2025-40946
CVEhttps://www.cve.org/CVERecord?id=CVE-2025-40946