Status: UPDATED
| Advisory ID: CVE-2025-40946
Key Details
| CVE | CVE-2025-40946 |
| CVSS Score / Version | 8.3 (High) / CVSS v3.1 |
| Updated | 2026-06-17 |
| CVSS Vector | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H |
| CVSS Prose | attack vector is adjacent; attack complexity is low; privileges required is none; user interaction is none; scope is unchanged; confidentiality impact is low; integrity impact is high; availability impact is high. |
| Affected products | see table below |
| Classified as | CWE-321 (Use of Hard-coded Cryptographic Key) |
Affected Products, Subsystems & Sectors
| Subsystems | General OT |
| Sectors | Multiple |
What to Know
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions), blueplanet 150 TL3 (All versions), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 25.0 NX3-33.0 NX3 (All versions), blueplanet 3.0 NX3-20.0 NX3 (All versions), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 3.0-5.0 NX1 (All versions), blueplanet 360 NX3 M6 (All versions), blueplanet 50.0 NX3-60.0 NX3 (All versions), blueplanet 87.0 TL3 (All versions), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91), blueplanet hybrid 10.0 TL3 (All versions), blueplanet hybrid 6.0 NH3-12.0 NH3 (All versions). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access. (NVD)
What to Do
Monitor Siemens's web page for any future patch releases.
References