Status: UPDATED | Advisory ID: CVE-2026-13584
| CVE | CVE-2026-13584 |
| CVSS Score / Version | |
| Updated | 2026-11-05 |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-R model MXR300-16 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-R model MXR300-32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-R model MXR300-64 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-R model MXR500-128 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-R model MXR500-256 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100-8-N32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100-8-P32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100-16-N32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100-16-P32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100S-N32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100S-P32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100S-8-N32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100S-8-P32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100S-16-N32 | ||
| Mitsubishi Electric Corporation | MELSEC MX Controller MX-F model MXF100S-16-P32 | ||
| Mitsubishi Electric Corporation | Master/local module RJ71GN11-T2 | ||
| Mitsubishi Electric Corporation | Master/local module RJ71GN11-SX | ||
| Mitsubishi Electric Corporation | Master/local module RJ71GN11-EIP | ||
| Mitsubishi Electric Corporation | Master/local module FX5-CCLGN-MS | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN interface board NZ81GN11-SX | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN interface board NZ81GN11-T2 | ||
| Mitsubishi Electric Corporation | Motion module RD78G4 | ||
| Mitsubishi Electric Corporation | Motion module RD78G8 | ||
| Mitsubishi Electric Corporation | Motion module RD78G16 | ||
| Mitsubishi Electric Corporation | Motion module RD78G64 | ||
| Mitsubishi Electric Corporation | Motion module RD78GHV | ||
| Mitsubishi Electric Corporation | Motion module RD78GHW | ||
| Mitsubishi Electric Corporation | Motion module FX5-40SSC-G | ||
| Mitsubishi Electric Corporation | Motion module FX5-80SSC-G | ||
| Mitsubishi Electric Corporation | MELSEC iQ-L Series Motion Module LD78G4 | ||
| Mitsubishi Electric Corporation | MELSEC iQ-L Series Motion module LD78G16 | ||
| Mitsubishi Electric Corporation | Motion Control Board MR-EM441G | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-32D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-32T | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-32TE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-32DT | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-32DTE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-32D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-32T | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-32TE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-32DT | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-32DTE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GNCF1-32D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GNCF1-32T | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GNCE3-32D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GNCE3-32DT | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN12A4-16D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN12A4-16DE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN12A2-16T | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN12A2-16TE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN12A42-16DT | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN12A42-16DTE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-16D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-16T | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2S1-16TE | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-16D | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-16T | ||
| Mitsubishi Electric Corporation | Block-type remote module NZ2GN2B1-16TE | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNSS2-8D | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNSS2-8D-K | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNSS2-8TE | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNSS2-8TE-K | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNSS2-16DTE | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNSS2-16DTE-K | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNS12A2-14DT | ||
| Mitsubishi Electric Corporation | Block-type remote module with safety functions NZ2GNS12A2-16DTE | ||
| Mitsubishi Electric Corporation | Analog-Digital converter module NZ2GN2S-60AD4 | ||
| Mitsubishi Electric Corporation | Analog-Digital converter module NZ2GN2B-60AD4 | ||
| Mitsubishi Electric Corporation | Digital-Analog converter module NZ2GN2S-60DA4 | ||
| Mitsubishi Electric Corporation | Digital-Analog converter module NZ2GN2B-60DA4 | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN compatible coupler NZ2FT-GN | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN compatible coupler NZ2CT-GN | ||
| Mitsubishi Electric Corporation | FPGA module NZ2GN2S-D41P01 | ||
| Mitsubishi Electric Corporation | FPGA module NZ2GN2S-D41D01 | ||
| Mitsubishi Electric Corporation | FPGA module NZ2GN2S-D41PD02 | ||
| Mitsubishi Electric Corporation | Tension meter LM7-1LG | ||
| Mitsubishi Electric Corporation | Tension meter LM7-2LG | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-J5-G | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-J5W-G | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-J5-G-HS | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-J5-G-RJ | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-J5-G-LL | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-J5D-G4 | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-J5 MR-MD333G | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-JET MR-JET-G | ||
| Mitsubishi Electric Corporation | AC Servo MELSERVO-JET MR-JET-G4-HS | ||
| Mitsubishi Electric Corporation | Liner Track System MTR-S series Linear track control module MTR-SCU00-4G | ||
| Mitsubishi Electric Corporation | Liner Track System MTR-S series Linear track control module MTR-SCU00-PG | ||
| Mitsubishi Electric Corporation | Inverter FR-A800/F800/E800 Series FR-A8NCG | ||
| Mitsubishi Electric Corporation | Inverter FR-A800/F800/E800 Series FR-A8NCG-S | ||
| Mitsubishi Electric Corporation | Inverter FR-A800/F800/E800 Series FR-A800-GN | ||
| Mitsubishi Electric Corporation | Inverter FR-A800/F800/E800 Series FR-E800-E | ||
| Mitsubishi Electric Corporation | Inverter FR-A800/F800/E800 Series FR-E800-SCE | ||
| Mitsubishi Electric Corporation | Inverter FR-D800 Series FR-D800-E | ||
| Mitsubishi Electric Corporation | Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN expansion unit FCU8-EX569 | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL | ||
| Mitsubishi Electric Corporation | Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3715-FHCBD | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3712-WXCBD | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3715-XRBA | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3715-XRBD | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3712-XRBA | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3712-XRBD | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3710-XRBA | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3710-XRBD | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3708-XRBA | ||
| Mitsubishi Electric Corporation | GOT3000 Series GT3708-XRBD | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN Communication Unit GT25-J71GN13-T2 | ||
| Mitsubishi Electric Corporation | Motion Control Software SWM-G | ||
| Mitsubishi Electric Corporation | Motion Control Software SWM-G-N1 | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M | ||
| Mitsubishi Electric Corporation | Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M | ||
| Mitsubishi Electric Corporation | Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51 | ||
| Mitsubishi Electric Corporation | Remote Station Communication LSI with GbE-PHY NZ2GACP620-60 | ||
| Mitsubishi Electric Corporation | Remote Station Communication LSI with GbE-PHY NZ2GACP620-300 | ||
| Mitsubishi Electric Corporation | Remote Station Communication LSI with GbE-PHY NZ2GACP621-90 | ||
| Mitsubishi Electric Corporation | Remote Station Communication LSI with GbE-PHY NZ2GACP621-720 | ||
| Mitsubishi Electric Corporation | CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M | ||
| Mitsubishi Electric Corporation | Remote station software development kit SW1DNC-GNSDK1S-M | ||
| Mitsubishi Electric Corporation | Remote station software development kit SW1DNC-GNSDK2S-M |
| Subsystems | Controllers & Field I/O |
| Sectors | Multiple |
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, MELSEC iQ-L Series Motion Module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly. (NVD)
An information tampering and denial-of-service (DoS) vulnerability exists in the CC-Link IE TSN communication protocol. An attacker with access to a CC-Link IE TSN network may be able to tamper with communication data by sending specially crafted packets under specific timing conditions (CVE-2026-13584). Mitigations/Workarounds: To prevent attackers from connecting attack devices, restrict physical access to the affected product and the CC-Link IE TSN network (manage site access, lock the control panel, lock Ethernet ports using port lock accessories). Use the affected products within a trusted network where communication with untrusted networks and hosts is blocked by a firewall or similar measures. Appropriately configure credentials and access privileges for network devices installed at the boundary between trusted networks and external networks.
Source: Mitsubishi Electric Corporation