← All Advisories
Reported from OT-Advisories.com as of

Rockwell Automation FactoryTalk Activation Manager Installer Custom Action Spawns SYSTEM-Level Console Window, Enabling Privilege Escalation

Last refreshed2026-11-17

Status: UPDATED  |  Advisory ID: CVE-2026-16675

Key Details

CVECVE-2026-16675
CVSS Score / Version
8.5 (High) / CVSS v4.0
Updated2026-09-01
Affected products
Rockwell Automation FactoryTalk® Activation Manager
Classified as
CWE-307 (Improper Restriction of Excessive Authentication Attempts)
Exploitation prediction (EPSS)
0.14% probability of exploitation in the next 30 days (3% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
Rockwell AutomationFactoryTalk® Activation Manager
SubsystemsGeneral OT
SectorsMultiple

What to Know

A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources. (NVD)

What to Do

Monitor Rockwell Automation's web page for any future patch releases.

https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-16675
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-16675
Vendor advisoryhttps://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html
Report compilation © 2026 OT-Advisories.com  ·  CC BY 4.0  ·  Source materials remain the property of their respective publishers as cited.