← All Advisories
Reported from OT-Advisories.com as of

Siemens SINEC NMS Password Reset Request Authorization Not Validated, Allowing Authenticated User to Reset Any Account Password

Last refreshed2026-11-16

Status: UPDATED  |  Advisory ID: CVE-2026-25654

Key Details

CVECVE-2026-25654
CVSS Score / Version
8.8 (High) / CVSS v3.1
Updated2026-06-17
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens SINEC NMS
Classified as
CWE-639 (Authorization Bypass Through User-Controlled Key)
Exploitation prediction (EPSS)
0.46% probability of exploitation in the next 30 days (41% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
SiemensSINEC NMS
SubsystemsEngineering & OT Operations Software
SectorsMultiple

What to Know

A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3). Affected products do not properly validate user authorization when processing password reset requests. This could allow an authenticated remote attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. (NVD)

What to Do

Vulnerability CVE-2026-25654: Affected products do not properly validate user authorization when processing password reset requests, allowing an authenticated remote attacker to bypass authorization checks and reset the password of any arbitrary user account. SINEC NMS All versions < V4.0 SP3 affected by CVE-2026-25654. Update to V4.0 SP3 or later version: https://support.industry.siemens.com/cs/ww/en/view/110000760/. Mitigations: Limit network access to trusted users and systems only.
Source: Siemens SSA-605717

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-25654
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-25654
Vendor advisoryhttps://cert-portal.siemens.com/productcert/html/ssa-605717.html
Report compilation © 2026 OT-Advisories.com  ·  CC BY 4.0  ·  Source materials remain the property of their respective publishers as cited.