Status: UPDATED | Advisory ID: CVE-2026-31417
| CVE | CVE-2026-31417 |
| CVSS Score / Version | 7.5 (High) / CVSS v3.1 |
| Updated | 2026-07-14 |
| CVSS Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| CVSS Prose | attack vector is network; attack complexity is low; privileges required is none; user interaction is none; scope is unchanged; confidentiality impact is none; integrity impact is none; availability impact is high. |
| Affected products | Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, and Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
| Classified as | CWE-191 (Integer Underflow (Wrap or Wraparound)) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
| Subsystems | General OT |
| Sectors | Multiple |
In the Linux kernel, the following vulnerability has been resolved:
net/x25: Fix overflow when accumulating packets
Add a check to ensure that `x25_sock.fraglen` does not overflow.
The `fraglen` also needs to be resetted when purging `fragment_queue` in
`x25_clear_queues()`. (NVD)
Monitor Siemens's web page for any future patch releases.
| Source | Reference |
|---|---|
| NVD | https://nvd.nist.gov/vuln/detail/CVE-2026-31417 |
| CVE | https://www.cve.org/CVERecord?id=CVE-2026-31417 |