Status: EPSS-IMMINENT | Advisory ID: CVE-2026-43499
| CVE | CVE-2026-43499 |
| CVSS Score / Version | |
| Updated | 2026-11-10 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Linux | Linux Kernel | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 TM MFP - GNU/Linux subsystem | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) |
| Subsystems | Controllers & Field I/O, OT Supporting Infrastructure |
| Sectors | All Sectors |
In the Linux kernel, the following vulnerability has been resolved:
rtmutex: Use waiter::task instead of current in remove_waiter()
remove_waiter() is used by the slowlock paths, but it is also used for
proxy-lock rollback in rt_mutex_start_proxy_lock() when invoked from
futex_requeue().
In the latter case waiter::task is not current, but remove_waiter()
operates on current for the dequeue operation. That results in several
problems:
1) the rbtree dequeue happens without waiter::task::pi_lock being held
2) the waiter task's pi_blocked_on state is not cleared, which leaves a
dangling pointer primed for UAF around.
3) rt_mutex_adjust_prio_chain() operates on the wrong top priority waiter
task
Use waiter::task instead of current in all related operations in
remove_waiter() to cure those problems.
[ tglx: Fixup rt_mutex_adjust_prio_chain(), add a comment and amend the
changelog ] (NVD)
Currently no fix is available. Siemens has identified the following specific mitigations that customers can apply to reduce the risk: Limit access to the interactive shell of the additional GNU/Linux subsystem to trusted personnel only. Only build and run applications from trusted sources.
Source: Siemens SSA-4579362 other advisories state the same guidance
Source: Siemens SSA-019113
Source: Siemens SSA-784472