Status: UPDATED | Advisory ID: CVE-2026-46306
| CVE | CVE-2026-46306 |
| CVSS Score / Version | |
| Updated | 2026-11-10 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Linux | Linux Kernel | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 TM MFP - GNU/Linux subsystem | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) |
| Subsystems | Controllers & Field I/O, OT Supporting Infrastructure |
| Sectors | All Sectors |
In the Linux kernel, the following vulnerability has been resolved:
flow_dissector: do not dissect PPPoE PFC frames
RFC 2516 Section 7 states that Protocol Field Compression (PFC) is NOT
RECOMMENDED for PPPoE. In practice, pppd does not support negotiating
PFC for PPPoE sessions, and the flow dissector driver has assumed an
uncompressed frame until the blamed commit.
During the review process of that commit [1], support for PFC is
suggested. However, having a compressed (1-byte) protocol field means
the subsequent PPP payload is shifted by one byte, causing 4-byte
misalignment for the network header and an unaligned access exception
on some architectures.
The exception can be reproduced by sending a PPPoE PFC frame to an
ethernet interface of a MIPS board, with RPS enabled, even if no PPPoE
session is active on that interface:
$ 0 : 00000000 80c40000 00000000 85144817
$ 4 : 00000008 00000100 80a75758 81dc9bb8
$ 8 : 00000010 8087ae2c 0000003d 00000000
$12 : 000000e0 00000039 00000000 00000000
$16 : 85043240 80a75758 81dc9bb8 00006488
$20 : 0000002f 00000007 85144810 80a70000
$24 : 81d1bda0 00000000
$28 : 81dc8000 81dc9aa8 00000000 805ead08
Hi : 00009d51
Lo : 2163358a
epc : 805e91f0 __skb_flow_dissect+0x1b0/0x1b50
ra : 805ead08 __skb_get_hash_net+0x74/0x12c
Status: 11000403 KERNEL EXL IE
Cause : 40800010 (ExcCode 04)
BadVA : 85144817
PrId : 0001992f (MIPS 1004Kc)
Call Trace:
[<805e91f0>] __skb_flow_dissect+0x1b0/0x1b50
[<805ead08>] __skb_get_hash_net+0x74/0x12c
[<805ef330>] get_rps_cpu+0x1b8/0x3fc
[<805fca70>] netif_receive_skb_list_internal+0x324/0x364
[<805fd120>] napi_complete_done+0x68/0x2a4
[<8058de5c>] mtk_napi_rx+0x228/0xfec
[<805fd398>] __napi_poll+0x3c/0x1c4
[<805fd754>] napi_threaded_poll_loop+0x234/0x29c
[<805fd848>] napi_threaded_poll+0x8c/0xb0
[<80053544>] kthread+0x104/0x12c
[<80002bd8>] ret_from_kernel_thread+0x14/0x1c
Code: 02d51821 1060045b 00000000 <8c640000> 3084000f 2c820005 144001a2 00042080 8e220000
To reduce the attack surface and maintain performance, do not process
PPPoE PFC frames.
[1] https://lore.kernel.org/r/20220630231016.GA392@debian.home (NVD)
Currently no fix is available. Siemens has identified the following specific mitigations that customers can apply to reduce the risk: Limit access to the interactive shell of the additional GNU/Linux subsystem to trusted personnel only. Only build and run applications from trusted sources.
Source: Siemens SSA-4579362 other advisories state the same guidance
Source: Siemens SSA-019113
Source: Siemens SSA-784472