Siemens SINEC INS sftp Upload API Unsanitized Input Allows Authenticated Remote Users to Inject OS Commands
Last refreshed2026-11-16
Status: UPDATED
| Advisory ID: CVE-2026-46746
Key Details
CVE
CVE-2026-46746
CVSS Score / Version
8.8 (High) / CVSS v3.1
Updated
2026-07-23
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is network; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens sinec_ins and Siemens SINEC INS
Classified as
CWE-78 (Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'))
Exploitation prediction (EPSS)
0.43% probability of exploitation in the next 30 days (38% percentile) -- FIRST.org's EPSS model.
Affected Products, Subsystems & Sectors
Vendor
Product
Affected Versions
Patch Status
Siemens
sinec_ins
Siemens
SINEC INS
Subsystems
OT Supporting Infrastructure
Sectors
Multiple
What to Know
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on the underlying operating system with the privileges of the affected service user (sinecins). (NVD)
What to Do
SINEC INS All versions < V1.0 SP2 Update 6 affected by all CVEs CVE-2026-46746 CVE-2026-46747 CVE-2026-46748 CVE-2026-46749 Update to V1.0 SP2 Update 6 or later version Source: Siemens SSA-860189