Status: UPDATED | Advisory ID: CVE-2026-52912
| CVE | CVE-2026-52912 |
| CVSS Score / Version | |
| Updated | 2026-11-10 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Linux | Linux Kernel | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) |
| Subsystems | Controllers & Field I/O, OT Supporting Infrastructure |
| Sectors | All Sectors |
In the Linux kernel, the following vulnerability has been resolved:
netfilter: nf_queue: hold bridge skb->dev while queued
br_pass_frame_up() rewrites skb->dev from the ingress port to the bridge
master before queueing bridge LOCAL_IN packets. NFQUEUE only holds
references on state.in/out and bridge physdevs, so a queued bridge
packet can retain a freed bridge master in skb->dev until reinjection.
When the verdict is reinjected later, br_netif_receive_skb() re-enters
the receive path with skb->dev still pointing at the freed bridge master,
triggering a use-after-free.
Store skb->dev in the queue entry, hold a reference on it for the queue
lifetime, and use the saved device when dropping queued packets during
NETDEV_DOWN handling. (NVD)
Currently no fix is available. Siemens has identified the following specific mitigations that customers can apply to reduce the risk: Limit access to the interactive shell of the additional GNU/Linux subsystem to trusted personnel only. Only build and run applications from trusted sources.
Source: Siemens SSA-4579361 other advisory states the same guidance
Source: Siemens SSA-019113