← All Advisories

CVE-2026-52912

Last refreshed2026-10-06

Status: UPDATED  |  Advisory ID: CVE-2026-52912

Key Details

CVECVE-2026-52912
CVSS Score / Version7.8 (High) / CVSS v3.1
Updated2026-09-08
CVSS VectorCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS Proseattack vector is local; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected productsSiemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, and Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP
Classified asCWE-416 (Use After Free)

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
SiemensSIMATIC S7-1500 CPU 1518-4 PN/DP MFP
SiemensSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP
SiemensSIPLUS S7-1500 CPU 1518-4 PN/DP MFP
SubsystemsGeneral OT
SectorsMultiple

What to Know

In the Linux kernel, the following vulnerability has been resolved:

netfilter: nf_queue: hold bridge skb->dev while queued

br_pass_frame_up() rewrites skb->dev from the ingress port to the bridge

master before queueing bridge LOCAL_IN packets. NFQUEUE only holds

references on state.in/out and bridge physdevs, so a queued bridge

packet can retain a freed bridge master in skb->dev until reinjection.

When the verdict is reinjected later, br_netif_receive_skb() re-enters

the receive path with skb->dev still pointing at the freed bridge master,

triggering a use-after-free.

Store skb->dev in the queue entry, hold a reference on it for the queue

lifetime, and use the saved device when dropping queued packets during

NETDEV_DOWN handling. (NVD)

What to Do

Monitor Siemens's web page for any future patch releases.

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-52912
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-52912