Status: UPDATED | Advisory ID: CVE-2026-64375
| CVE | CVE-2026-64375 |
| CVSS Score / Version | 7.8 (High) / CVSS v3.1 |
| Updated | 2026-09-08 |
| CVSS Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CVSS Prose | attack vector is local; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high. |
| Affected products | Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, and Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
| Subsystems | General OT |
| Sectors | Multiple |
In the Linux kernel, the following vulnerability has been resolved:
proc: protect ptrace_may_access() with exec_update_lock (FD links)
proc_pid_get_link() and proc_pid_readlink() currently look up the task from
the pid once, then do the ptrace access check on that task, then look up
the task from the pid a second time to do the actual access.
That's racy in several ways.
To fix it, pass the task to the ->proc_get_link() handler, and instead of
proc_fd_access_allowed(), introduce a new helper call_proc_get_link() that
looks up and locks the task, does the access check, and calls
->proc_get_link(). (NVD)
Monitor Siemens's web page for any future patch releases.
| Source | Reference |
|---|---|
| NVD | https://nvd.nist.gov/vuln/detail/CVE-2026-64375 |
| CVE | https://www.cve.org/CVERecord?id=CVE-2026-64375 |