Status: UPDATED | Advisory ID: CVE-2026-64411
| CVE | CVE-2026-64411 |
| CVSS Score / Version | |
| Updated | 2026-11-10 |
| CVSS Vector | |
| CVSS Prose | |
| Affected products | |
| Classified as | |
| Exploitation prediction (EPSS) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Linux | Linux Kernel | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) |
| Subsystems | Controllers & Field I/O, OT Supporting Infrastructure |
| Sectors | All Sectors |
In the Linux kernel, the following vulnerability has been resolved:
netfilter: ebtables: terminate table name before find_table_lock()
update_counters() and compat_update_counters() forward a user-supplied
32-byte table name to find_table_lock() without NUL-terminating it. On a
lookup miss, find_inlist_lock() calls try_then_request_module(..., "%s%s",
"ebtable_", name), and vsnprintf() reads past the name field and the
stack object until it hits a zero byte.
BUG: KASAN: stack-out-of-bounds in string (lib/vsprintf.c:648 lib/vsprintf.c:730)
Read of size 1 at addr ffff8880119dfb20 by task exploit/147
Call Trace:
...
string (lib/vsprintf.c:648 lib/vsprintf.c:730)
vsnprintf (lib/vsprintf.c:2945)
__request_module (kernel/module/kmod.c:150)
do_update_counters.isra.0 (net/bridge/netfilter/ebtables.c:371 net/bridge/netfilter/ebtables.c:380)
update_counters (net/bridge/netfilter/ebtables.c:1440)
do_ebt_set_ctl (net/bridge/netfilter/ebtables.c:2573)
nf_setsockopt (net/netfilter/nf_sockopt.c:101)
ip_setsockopt (net/ipv4/ip_sockglue.c:1424)
raw_setsockopt (net/ipv4/raw.c:847)
__sys_setsockopt (net/socket.c:2393)
...
compat_do_replace() shares the same unterminated name via
compat_copy_ebt_replace_from_user(); terminate it there too so all
find_table_lock() callers behave alike. The other callers already
terminate the name after the copy. (NVD)
Currently no fix is available. Siemens has identified the following specific mitigations that customers can apply to reduce the risk: Limit access to the interactive shell of the additional GNU/Linux subsystem to trusted personnel only. Only build and run applications from trusted sources.
Source: Siemens SSA-4579361 other advisory states the same guidance
Source: Siemens SSA-019113