Status: UPDATED | Advisory ID: CVE-2026-64423
| CVE | CVE-2026-64423 |
| CVSS Score / Version | 7.8 (High) / CVSS v3.1 |
| Updated | 2026-09-08 |
| CVSS Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CVSS Prose | attack vector is local; attack complexity is low; privileges required is low; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high. |
| Affected products | Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, and Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
| Classified as | CWE-416 (Use After Free) |
| Vendor | Product | Affected Versions | Patch Status |
|---|---|---|---|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | ||
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | ||
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
| Subsystems | General OT |
| Sectors | Multiple |
In the Linux kernel, the following vulnerability has been resolved:
ipv4: igmp: remove multicast group from hash table on device destruction
When a device is destroyed under RTNL, ip_mc_destroy_dev() iterates through
the multicast list and calls ip_ma_put() on each membership, scheduling
them for RCU reclamation. However, they are not unlinked from the device's
multicast hash table (mc_hash).
Since the device remains published in dev->ip_ptr until after
ip_mc_destroy_dev() completes, concurrent RCU readers traversing mc_hash
can still locate and access the multicast group after its refcount is
decremented. If the RCU callback runs and frees the group while a reader is
accessing it, a use-after-free occurs.
Fix this by unlinking the multicast group from mc_hash using
ip_mc_hash_remove() before scheduling it for reclamation.
BUG: KASAN: slab-use-after-free in ip_check_mc_rcu+0x149/0x3f0
Read of size 4 at addr ffff888009bf1408 by task mausezahn/2276
Call Trace:
<IRQ>
dump_stack_lvl+0x67/0x90
print_report+0x175/0x7c0
kasan_report+0x147/0x180
ip_check_mc_rcu+0x149/0x3f0
udp_v4_early_demux+0x36d/0x12d0
ip_rcv_finish_core+0xb8b/0x1390
ip_rcv_finish+0x54/0x120
NF_HOOK+0x213/0x2b0
__netif_receive_skb+0x126/0x340
process_backlog+0x4f2/0xf00
__napi_poll+0x92/0x2c0
net_rx_action+0x583/0xc60
handle_softirqs+0x236/0x7f0
do_softirq+0x57/0x80
</IRQ>
Allocated by task 2239:
kasan_save_track+0x3e/0x80
__kasan_kmalloc+0x72/0x90
____ip_mc_inc_group+0x31a/0xa40
__ip_mc_join_group+0x334/0x3f0
do_ip_setsockopt+0x16fa/0x2010
ip_setsockopt+0x3f/0x90
do_sock_setsockopt+0x1ad/0x300
Freed by task 0:
kasan_save_track+0x3e/0x80
kasan_save_free_info+0x40/0x50
__kasan_slab_free+0x3a/0x60
__rcu_free_sheaf_prepare+0xd4/0x220
rcu_free_sheaf+0x36/0x190
rcu_core+0x8d9/0x12f0
handle_softirqs+0x236/0x7f0 (NVD)
Monitor Siemens's web page for any future patch releases.
| Source | Reference |
|---|---|
| NVD | https://nvd.nist.gov/vuln/detail/CVE-2026-64423 |
| CVE | https://www.cve.org/CVERecord?id=CVE-2026-64423 |