Siemens License Server (All Versions Before V5.3) Path Traversal via Unsanitized User Input Exposes Arbitrary Application Files to Unauthenticated Remote Attackers
Last refreshed2026-11-19
Status: UPDATED
| Advisory ID: CVE-2026-69109
Key Details
CVE
CVE-2026-69109
CVSS Score / Version
7.5 (High) / CVSS v3.1
Updated
2026-10-23
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS Prose
attack vector is network; attack complexity is low; privileges required is none; user interaction is none; scope is unchanged; confidentiality impact is high; integrity impact is none; availability impact is none.
Affected products
Siemens License Server (SLS)
Classified as
CWE-35 (Path Traversal: '.../...//')
Exploitation prediction (EPSS)
0.62% probability of exploitation in the next 30 days (51% percentile) -- FIRST.org's EPSS model.
Affected Products, Subsystems & Sectors
Vendor
Product
Affected Versions
Patch Status
Siemens
Siemens License Server (SLS)
Subsystems
General OT
Sectors
Multiple
What to Know
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.3). The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application. (NVD)
What to Do
Siemens License Server (SLS): All versions < V5.3 affected by CVE-2026-69109. Update to V5.3 or later version. https://support.sw.siemens.com/product/1586485382/ Source: Siemens SSA-077553