← All Advisories

CVE-2026-85114

Last refreshed2026-10-13

Status: UPDATED  |  Advisory ID: CVE-2026-85114

Key Details

CVECVE-2026-85114
CVSS Score / Version
7.5 (High) / CVSS v3.1
Updated2026-10-13
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CVSS Prose
attack vector is network; attack complexity is low; privileges required is none; user interaction is none; scope is unchanged; confidentiality impact is none; integrity impact is high; availability impact is none.
Affected products
Siemens .NET Client Library for SIMATIC S7 Webserver API
Classified as
CWE-22 (Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'))

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
Siemens.NET Client Library for SIMATIC S7 Webserver API
SubsystemsGeneral OT
SectorsMultiple

What to Know

A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.61). Affected applications do not properly validate filenames received from remote servers during ticket downloads.

This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application. (NVD)

What to Do

Monitor Siemens's web page for any future patch releases.

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-85114
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-85114